What size generator do I need?
Size for two numbers: running watts (everything on at once, plus 20% headroom) and starting watts (the running total plus the one biggest motor start). Check both against the generator's spec sheet.
| What you run | Running total | Starting watts | Generator size | Home standby |
|---|---|---|---|---|
| Outage essentials | 2,885 W | 4,360 W | 3,500 W | 10 kW |
| Essentials and a well pump | 3,885 W | 5,360 W | 5,000 W | 10 kW |
| Essentials with a window AC | 3,510 W | 4,610 W | 4,500 W | 10 kW |
| Refrigerator only | 400 W | 1,200 W | 500 W | 10 kW |
| Sump pump only | 1,050 W | 2,150 W | 1,500 W | 10 kW |
| Whole house, gas heat and hot water | 10,545 W | 13,045 W | 13,000 W | 14 kW |
| All-electric house, everything on | 22,545 W | 25,045 W | 27,500 W | 28 kW |
| 30 amp RV | 2,360 W | 3,360 W | 3,000 W | 10 kW |
| 50 amp RV with two ACs | 6,220 W | 7,520 W | 7,500 W | 10 kW |
- Outage essentials: Refrigerator, 1/2 hp sump pump, furnace blower, 10 LED bulbs, TV, router and 2 chargers.
- Essentials and a well pump: The essentials plus a 1/2 hp well pump.
- Essentials with a window AC: Refrigerator, sump pump, 10,000 BTU window AC, 10 LED bulbs, TV, router and 2 chargers.
- Refrigerator only: One refrigerator.
- Sump pump only: One 1/2 hp sump pump.
- Whole house, gas heat and hot water: Refrigerator, freezer, 3 ton central AC and its blower, sump pump, microwave, washer, garage door, 20 LED bulbs, 2 TVs, router, 3 chargers.
- All-electric house, everything on: The whole-house list plus an electric water heater, electric dryer and one range burner.
- 30 amp RV: 13,500 BTU roof AC, RV refrigerator on electric, TV, 6 LED bulbs and a charger.
- 50 amp RV with two ACs: Two 15,000 BTU roof ACs, RV refrigerator, microwave, TV, 10 LED bulbs and 2 chargers.
Running and starting watts for common appliances
From manufacturer wattage guides. Where a guide gives a range we use the top, so the sizes err high. The guides disagree most on refrigerators: Honda lists 132 to 192 W running for an ENERGY STAR model, Champion 150 to 400 W and Generac 700 W. Your appliance's nameplate or manual is the better number.
| Appliance | Running watts | Starting watts | Source |
|---|---|---|---|
| Refrigerator | 400 | 1,200 | Champion |
| Freezer | 500 | 1,000 | Champion |
| Sump pump (1/3 hp) | 800 | 1,300 | Honda |
| Sump pump (1/2 hp) | 1,050 | 2,150 | Honda |
| Well pump (1/2 hp) | 1,000 | 2,000 | Champion |
| Well pump (1 hp) | 2,000 | 4,000 | Champion |
| Furnace blower (1/2 hp) | 875 | 2,350 | Honda |
| Window AC (5,000 BTU) | 600 | 1,200 | Champion |
| Window AC (10,000 BTU) | 1,500 | 2,200 | Honda |
| Central AC (2 ton) (240 V) | 2,500 | 4,500 | Champion |
| Central AC (3 ton) (240 V) | 3,500 | 6,000 | Champion |
| Central AC (4 ton) (240 V) | 5,000 | 8,000 | Champion |
| Electric water heater (240 V) | 4,500 | 4,500 | Honda |
| Microwave (1,000 W) | 1,500 | 1,500 | Honda |
| Coffee maker | 1,200 | 1,200 | Generac |
| Electric range burner (8 in) (240 V) | 2,100 | 2,100 | Honda |
| Washing machine | 1,000 | 2,300 | Champion |
| Electric clothes dryer (240 V) | 5,400 | 6,750 | Honda |
| Space heater | 1,500 | 1,500 | Champion |
| TV (flat screen) | 190 | 190 | Honda |
| LED light bulb | 15 | 15 | Champion |
| Modem and router | 20 | 20 | Champion |
| Phone or laptop charger | 100 | 100 | Champion |
| CPAP with heated humidifier | 120 | 120 | Champion |
| Ceiling fan | 75 | 75 | Champion |
| Garage door opener | 720 | 1,420 | Honda |
| RV air conditioner (13,500 BTU) | 1,800 | 2,800 | Honda |
| RV air conditioner (15,000 BTU) | 2,000 | 3,300 | Honda |
| RV refrigerator (on electric) | 180 | 600 | Honda |
How many watts does it take to run a house?
A house with gas heat and gas hot water, a 3 ton central AC, refrigerator, freezer, sump pump, microwave, washer, lights and electronics draws about 10,545 W with everything on, and needs 13,045 W for the moment the AC starts. That calls for about 13,000 running watts, which a 14 kW home standby unit covers. An all-electric house with the water heater, dryer and a range burner on as well reaches 22,545 W, a 28 kW unit. Few houses run everything at once, so a dealer sizing a standby generator looks at which loads actually overlap.
What size generator to run a refrigerator?
A refrigerator runs on 400 W or less, but its compressor needs about 1,200 W for a moment every time it starts. So the generator needs at least 500 running watts and 1,200 starting watts. A refrigerator, a freezer and 5 LED bulbs together need 1,500 running watts and 1,775 starting watts.
What size generator for a 30 amp RV?
A 30 amp RV inlet carries 120 V x 30 A = 3,600 W at most. A 13,500 BTU roof AC with the fridge, TV, lights and a charger runs 2,360 W and needs 3,360 W to start the AC, so look for 3,000 running watts with at least 3,360 starting watts. Cummins, which builds RV generators, puts the practical minimum for a 30 amp RV with AC at 2,500 to 2,800 W and notes that a 3,600 W generator matches what shore power gives you.
What size generator for a 50 amp RV?
A 50 amp RV has two separate 120 V legs of 50 A each, 12,000 W in all. Two 15,000 BTU ACs with the fridge, a microwave, TV and lights run 6,220 W and need 7,520 W to start one AC, so a generator of about 7,500 running watts. Cummins lists 5,500 to 8,000 W for a Class A coach with two ACs. To feed both legs, the generator needs 120/240 V output and a 50 A outlet.
How the calculator works
- Running total: each appliance's running watts x its quantity, added up.
- Biggest surge: the largest gap between starting and running watts of any one appliance. Motors start one at a time, so only one surge counts, even with two of the same AC.
- Starting watts needed = running total + biggest surge. Compare it with the generator's starting (peak or maximum) rating.
- Generator size = running total x 1.2, rounded up to the next 500 W. Cummins advises adding 20 to 25% when sizing a home generator, for loads you add later; the calculator uses 20%.
- Home standby: the smallest of 10, 14, 18, 22, 24, 26 and 28 kW (Generac's current home standby sizes) at or above that figure.
Running watts vs starting watts
Spec sheets give two numbers: rated or running watts, which the generator can supply continuously, and starting, peak or maximum watts, which it can supply for a moment. Anything with a motor or compressor needs extra power to start: Generac's worksheet says starting watts are typically 2 times running watts, and Cummins says some motors need 3 to 5 times. Heaters, coffee makers and lights need no extra. When the chart and your appliance's nameplate disagree, use the nameplate.
Generator safety: carbon monoxide and transfer switches
Run a portable generator outside only, at least 20 feet from the house with the exhaust pointed away from doors, windows and vents, never in a garage, basement, crawlspace or on a porch, even with the doors open. CPSC counts an average of nearly 100 deaths a year in the US from carbon monoxide from portable generators; keep battery CO alarms inside and look for a model with a CO shut-off. To power house circuits, have an electrician install a transfer switch, because plugging a generator into a wall outlet (backfeeding) can electrocute utility workers.
Sources
Running and starting watts: Honda generator wattage estimation guide, Champion Power Equipment generator wattage chart and Generac generator wattage worksheet. Sizing method (running total plus the largest motor start): Cummins, What size portable generator do you need? Headroom (20 to 25%): Cummins, Expert tips for sizing your home generator. RV service (30 A, 3,600 W; 50 A, two legs, 12,000 W) and RV sizes: Cummins, What size generator do I need to power an RV? Standby sizes: Generac home standby generators (checked November 2026). Safety: CPSC, Portable Generator Hazards and CPSC, Winter Storm May Knock Out Power (2026).