Generator size calculator

To keep a refrigerator, sump pump, furnace blower, lights, TV and router going in an outage, you need a generator rated at least 3,500 running watts that can also deliver 4,360 starting watts. Start from a list below or build your own; every running and starting figure is editable.

Refrigerator
Sump pump (1/2 hp)
Furnace blower (1/2 hp)
LED light bulb
TV (flat screen)
Modem and router
Phone or laptop charger
Generator size3,500 Wrunning watts, with 20% headroom
Starting watts4,360 Wbiggest start: Furnace blower (1/2 hp)
Running total2,885 Weverything on at once
Home standby10 kWsmallest common standby size that covers it

To run these 17 items at once, look for a generator rated at least 3,500 running watts that can also deliver 4,360 starting watts.

Watts: Honda, Champion and Generac wattage guides, using the top of a range where one is given. Your appliance's nameplate is better; edit any figure. Starting watts = running total + the biggest single motor start.

What size generator do I need?

Size for two numbers: running watts (everything on at once, plus 20% headroom) and starting watts (the running total plus the one biggest motor start). Check both against the generator's spec sheet.

What you run Running total Starting watts Generator size Home standby
Outage essentials 2,885 W 4,360 W 3,500 W 10 kW
Essentials and a well pump 3,885 W 5,360 W 5,000 W 10 kW
Essentials with a window AC 3,510 W 4,610 W 4,500 W 10 kW
Refrigerator only 400 W 1,200 W 500 W 10 kW
Sump pump only 1,050 W 2,150 W 1,500 W 10 kW
Whole house, gas heat and hot water 10,545 W 13,045 W 13,000 W 14 kW
All-electric house, everything on 22,545 W 25,045 W 27,500 W 28 kW
30 amp RV 2,360 W 3,360 W 3,000 W 10 kW
50 amp RV with two ACs 6,220 W 7,520 W 7,500 W 10 kW
  • Outage essentials: Refrigerator, 1/2 hp sump pump, furnace blower, 10 LED bulbs, TV, router and 2 chargers.
  • Essentials and a well pump: The essentials plus a 1/2 hp well pump.
  • Essentials with a window AC: Refrigerator, sump pump, 10,000 BTU window AC, 10 LED bulbs, TV, router and 2 chargers.
  • Refrigerator only: One refrigerator.
  • Sump pump only: One 1/2 hp sump pump.
  • Whole house, gas heat and hot water: Refrigerator, freezer, 3 ton central AC and its blower, sump pump, microwave, washer, garage door, 20 LED bulbs, 2 TVs, router, 3 chargers.
  • All-electric house, everything on: The whole-house list plus an electric water heater, electric dryer and one range burner.
  • 30 amp RV: 13,500 BTU roof AC, RV refrigerator on electric, TV, 6 LED bulbs and a charger.
  • 50 amp RV with two ACs: Two 15,000 BTU roof ACs, RV refrigerator, microwave, TV, 10 LED bulbs and 2 chargers.

Running and starting watts for common appliances

From manufacturer wattage guides. Where a guide gives a range we use the top, so the sizes err high. The guides disagree most on refrigerators: Honda lists 132 to 192 W running for an ENERGY STAR model, Champion 150 to 400 W and Generac 700 W. Your appliance's nameplate or manual is the better number.

Appliance Running watts Starting watts Source
Refrigerator 400 1,200 Champion
Freezer 500 1,000 Champion
Sump pump (1/3 hp) 800 1,300 Honda
Sump pump (1/2 hp) 1,050 2,150 Honda
Well pump (1/2 hp) 1,000 2,000 Champion
Well pump (1 hp) 2,000 4,000 Champion
Furnace blower (1/2 hp) 875 2,350 Honda
Window AC (5,000 BTU) 600 1,200 Champion
Window AC (10,000 BTU) 1,500 2,200 Honda
Central AC (2 ton) (240 V) 2,500 4,500 Champion
Central AC (3 ton) (240 V) 3,500 6,000 Champion
Central AC (4 ton) (240 V) 5,000 8,000 Champion
Electric water heater (240 V) 4,500 4,500 Honda
Microwave (1,000 W) 1,500 1,500 Honda
Coffee maker 1,200 1,200 Generac
Electric range burner (8 in) (240 V) 2,100 2,100 Honda
Washing machine 1,000 2,300 Champion
Electric clothes dryer (240 V) 5,400 6,750 Honda
Space heater 1,500 1,500 Champion
TV (flat screen) 190 190 Honda
LED light bulb 15 15 Champion
Modem and router 20 20 Champion
Phone or laptop charger 100 100 Champion
CPAP with heated humidifier 120 120 Champion
Ceiling fan 75 75 Champion
Garage door opener 720 1,420 Honda
RV air conditioner (13,500 BTU) 1,800 2,800 Honda
RV air conditioner (15,000 BTU) 2,000 3,300 Honda
RV refrigerator (on electric) 180 600 Honda

How many watts does it take to run a house?

A house with gas heat and gas hot water, a 3 ton central AC, refrigerator, freezer, sump pump, microwave, washer, lights and electronics draws about 10,545 W with everything on, and needs 13,045 W for the moment the AC starts. That calls for about 13,000 running watts, which a 14 kW home standby unit covers. An all-electric house with the water heater, dryer and a range burner on as well reaches 22,545 W, a 28 kW unit. Few houses run everything at once, so a dealer sizing a standby generator looks at which loads actually overlap.

What size generator to run a refrigerator?

A refrigerator runs on 400 W or less, but its compressor needs about 1,200 W for a moment every time it starts. So the generator needs at least 500 running watts and 1,200 starting watts. A refrigerator, a freezer and 5 LED bulbs together need 1,500 running watts and 1,775 starting watts.

What size generator for a 30 amp RV?

A 30 amp RV inlet carries 120 V x 30 A = 3,600 W at most. A 13,500 BTU roof AC with the fridge, TV, lights and a charger runs 2,360 W and needs 3,360 W to start the AC, so look for 3,000 running watts with at least 3,360 starting watts. Cummins, which builds RV generators, puts the practical minimum for a 30 amp RV with AC at 2,500 to 2,800 W and notes that a 3,600 W generator matches what shore power gives you.

What size generator for a 50 amp RV?

A 50 amp RV has two separate 120 V legs of 50 A each, 12,000 W in all. Two 15,000 BTU ACs with the fridge, a microwave, TV and lights run 6,220 W and need 7,520 W to start one AC, so a generator of about 7,500 running watts. Cummins lists 5,500 to 8,000 W for a Class A coach with two ACs. To feed both legs, the generator needs 120/240 V output and a 50 A outlet.

How the calculator works

  1. Running total: each appliance's running watts x its quantity, added up.
  2. Biggest surge: the largest gap between starting and running watts of any one appliance. Motors start one at a time, so only one surge counts, even with two of the same AC.
  3. Starting watts needed = running total + biggest surge. Compare it with the generator's starting (peak or maximum) rating.
  4. Generator size = running total x 1.2, rounded up to the next 500 W. Cummins advises adding 20 to 25% when sizing a home generator, for loads you add later; the calculator uses 20%.
  5. Home standby: the smallest of 10, 14, 18, 22, 24, 26 and 28 kW (Generac's current home standby sizes) at or above that figure.

Running watts vs starting watts

Spec sheets give two numbers: rated or running watts, which the generator can supply continuously, and starting, peak or maximum watts, which it can supply for a moment. Anything with a motor or compressor needs extra power to start: Generac's worksheet says starting watts are typically 2 times running watts, and Cummins says some motors need 3 to 5 times. Heaters, coffee makers and lights need no extra. When the chart and your appliance's nameplate disagree, use the nameplate.

Generator safety: carbon monoxide and transfer switches

Run a portable generator outside only, at least 20 feet from the house with the exhaust pointed away from doors, windows and vents, never in a garage, basement, crawlspace or on a porch, even with the doors open. CPSC counts an average of nearly 100 deaths a year in the US from carbon monoxide from portable generators; keep battery CO alarms inside and look for a model with a CO shut-off. To power house circuits, have an electrician install a transfer switch, because plugging a generator into a wall outlet (backfeeding) can electrocute utility workers.

Sources

Running and starting watts: Honda generator wattage estimation guide, Champion Power Equipment generator wattage chart and Generac generator wattage worksheet. Sizing method (running total plus the largest motor start): Cummins, What size portable generator do you need? Headroom (20 to 25%): Cummins, Expert tips for sizing your home generator. RV service (30 A, 3,600 W; 50 A, two legs, 12,000 W) and RV sizes: Cummins, What size generator do I need to power an RV? Standby sizes: Generac home standby generators (checked November 2026). Safety: CPSC, Portable Generator Hazards and CPSC, Winter Storm May Knock Out Power (2026).

Related calculators