AC size and BTU calculator

A 1,500 sq ft house needs about 24,000 BTU of cooling, a 2 ton central AC, by the usual rule of thumb, and a 500 sq ft room needs a 12,000 BTU window unit by ENERGY STAR's chart. Pick your type of AC below. For a central system, a Manual J load calculation sets the real size.

For example the Mid-Atlantic, the Carolinas, Tennessee, Missouri, Kansas

Cooling estimate24,000 BTUper hour, 16 BTU per sq ft
Tons212,000 BTU per hour per ton
Standard size2 tonsnearest size sold
Rule-of-thumb range1.5 to 2.5 tonsnewer house to old rule of thumb

For a 1,500 sq ft house in a mixed climate, plan on about 24,000 BTU per hour, a 2 ton central AC. An ACCA Manual J load calculation from your contractor sets the real size, and newer, tighter houses often need less.

Whole-house figures are rules of thumb: 20 BTU per sq ft is the old contractor rule, 12 fits many newer houses. Only a Manual J load calculation sizes a real system.

What size AC unit do I need for my square footage?

Central AC sizes for a whole house with 8 ft ceilings, rounded to the nearest size sold. The first column is ENERGY STAR's room chart, for one open space cooled by a window unit or mini split.

Floor area One room (ENERGY STAR) Central, hot Central, mixed Central, cool
500 sq ft 12,000 BTU 1.5 tons 1.5 tons 1.5 tons
600 sq ft 14,000 BTU 1.5 tons 1.5 tons 1.5 tons
700 sq ft 18,000 BTU 1.5 tons 1.5 tons 1.5 tons
800 sq ft 18,000 BTU 1.5 tons 1.5 tons 1.5 tons
900 sq ft 18,000 BTU 1.5 tons 1.5 tons 1.5 tons
1,000 sq ft 21,000 BTU 1.5 tons 1.5 tons 1.5 tons
1,200 sq ft 23,000 BTU 2 tons 1.5 tons 1.5 tons
1,400 sq ft 24,000 BTU 2.5 tons 2 tons 1.5 tons
1,500 sq ft 30,000 BTU 2.5 tons 2 tons 1.5 tons
1,600 sq ft 30,000 BTU 2.5 tons 2 tons 1.5 tons
1,800 sq ft 30,000 BTU 3 tons 2.5 tons 2 tons
2,000 sq ft 34,000 BTU 3.5 tons 2.5 tons 2 tons
2,200 sq ft 34,000 BTU 3.5 tons 3 tons 2 tons
2,400 sq ft 34,000 BTU 4 tons 3 tons 2.5 tons
2,500 sq ft 34,000 BTU 4 tons 3.5 tons 2.5 tons
2,800 sq ft Over chart 5 tons 3.5 tons 3 tons
3,000 sq ft Over chart 5 tons 4 tons 3 tons

Hot is 20 BTU per sq ft (Florida, Texas, Arizona, Nevada, the Gulf Coast), mixed 16 (the Mid-Atlantic, the Carolinas, Tennessee, Missouri, Kansas) and cool 12 (New England, the Great Lakes, the Upper Midwest, the Pacific Northwest). These are rules of thumb, not a load calculation.

Rules of thumb disagree with each other. Carrier's is 20 BTU per sq ft, which puts a 1,500 sq ft house at 2.5 tons; Trane's sizing table puts the same house at 3 tons; and a DOE Building America study found Manual J loads near 1.7 tons for 2,223 sq ft houses built to the 2009 energy code in both Chicago and Orlando. Newer, well-insulated houses with good windows sit at the low end. Older houses with leaky ducts and big west-facing windows sit at the high end.

What size window AC do I need?

ENERGY STAR's room air conditioner chart, for an 8 ft ceiling, with the common size to buy. Window units on the ENERGY STAR certified list cluster at 5,000, 6,000, 8,000, 10,000, 12,000, 14,000, 18,000, 24,000 BTU, so a chart value between two of those rounds up.

Room area Capacity needed Window unit to buy BTU per sq ft
100 to 150 sq ft 5,000 BTU 5,000 BTU 40
150 to 250 sq ft 6,000 BTU 6,000 BTU 30
250 to 300 sq ft 7,000 BTU 8,000 BTU 25.5
300 to 350 sq ft 8,000 BTU 8,000 BTU 24.6
350 to 400 sq ft 9,000 BTU 10,000 BTU 24
400 to 450 sq ft 10,000 BTU 10,000 BTU 23.5
450 to 550 sq ft 12,000 BTU 12,000 BTU 24
550 to 700 sq ft 14,000 BTU 14,000 BTU 22.4
700 to 1,000 sq ft 18,000 BTU 18,000 BTU 21.2
1,000 to 1,200 sq ft 21,000 BTU 24,000 BTU 19.1
1,200 to 1,400 sq ft 23,000 BTU 24,000 BTU 17.7
1,400 to 1,500 sq ft 24,000 BTU 24,000 BTU 16.6
1,500 to 2,000 sq ft 30,000 BTU Two units 17.1
2,000 to 2,500 sq ft 34,000 BTU Two units 15.1

Then adjust, as ENERGY STAR does:

  • Heavily shaded room: take off 10%.
  • Very sunny room: add 10%.
  • More than two people use the room regularly: add 600 BTU for each extra person.
  • The unit cools a kitchen: add 4,000 BTU.
  • Ceiling over 8 ft: ENERGY STAR says to size up but gives no figure. We add 12.5% per 2 ft, the middle of Penn State's 10 to 15%.

What size mini split do I need?

A single-zone mini split cools one room or one open area, so the same ENERGY STAR chart applies. Indoor heads are sold in 6,000, 9,000, 12,000, 15,000, 18,000, 24,000, 30,000, 36,000 BTU sizes, the standard capacities on the ENERGY STAR heat pump list.

Room Area Capacity needed Head size If very sunny
10 x 12 ft 120 sq ft 5,000 BTU 6,000 BTU 6,000 BTU
12 x 12 ft 144 sq ft 5,000 BTU 6,000 BTU 6,000 BTU
12 x 15 ft 180 sq ft 6,000 BTU 6,000 BTU 9,000 BTU
14 x 16 ft 224 sq ft 6,000 BTU 6,000 BTU 9,000 BTU
16 x 20 ft 320 sq ft 8,000 BTU 9,000 BTU 9,000 BTU
20 x 20 ft 400 sq ft 10,000 BTU 12,000 BTU 12,000 BTU
20 x 25 ft 500 sq ft 12,000 BTU 12,000 BTU 15,000 BTU
25 x 30 ft 750 sq ft 18,000 BTU 18,000 BTU 24,000 BTU

For a multi-zone system, size each room's head from the chart, then let the installer match the outdoor unit. A mini split that also heats should be checked against the heating load too; our heat pump size calculator does that.

How many BTU in a ton?

One ton of cooling is 12,000 BTU per hour. The unit comes from ice: melting one ton (2,000 lb) of ice over 24 hours takes 288,000 BTU, and 288,000 divided by 24 is 12,000. To turn BTU into tons, divide by 12,000: 30,000 BTU is 2.5 tons.

Tons BTU per hour House size, old rule House size, newer house
1 ton 12,000 600 sq ft 1,000 sq ft
1.5 tons 18,000 900 sq ft 1,500 sq ft
2 tons 24,000 1,200 sq ft 2,000 sq ft
2.5 tons 30,000 1,500 sq ft 2,500 sq ft
3 tons 36,000 1,800 sq ft 3,000 sq ft
3.5 tons 42,000 2,100 sq ft 3,500 sq ft
4 tons 48,000 2,400 sq ft 4,000 sq ft
5 tons 60,000 3,000 sq ft 5,000 sq ft

Old rule: 20 BTU per sq ft (1 ton per 600 sq ft). Newer house: 12 BTU per sq ft (1 ton per 1,000 sq ft). Home central systems run from 1.5 to 5 tons.

How many BTU per square foot?

For a single room, ENERGY STAR's chart works out to between 15 and 40 BTU per sq ft: small rooms need the most per square foot, large open rooms the least. For a whole house the common contractor rule is 20 BTU per sq ft. Load calculations on houses built to recent energy codes often come in near 12 or below; the DOE study above found about 9.3.

How the calculator works

For a window unit or a mini split:

  1. Find the room's area on the ENERGY STAR chart. That is the capacity for an 8 ft ceiling.
  2. Take 10% off for a heavily shaded room or add 10% for a very sunny one, and add 6.25% for each foot of ceiling over 8 ft.
  3. Add 600 BTU for each regular occupant past two, and 4,000 BTU for a kitchen.
  4. Round up to the next common size: window units from 5,000 to 24,000 BTU, mini split heads from 6,000 to 36,000.

For central AC:

  1. Multiply the floor area by the BTU per sq ft for your climate: 20 for hot, 16 for mixed, 12 for cool. You can type your own figure.
  2. Apply the same sun and ceiling adjustments.
  3. Divide by 12,000 to get tons, then round to the nearest size sold (1.5, 2, 2.5, 3, 3.5, 4 or 5 tons).

The climate setting is our judgement: no published table ties BTU per square foot to climate, so we put hot climates at the old rule of thumb and cool climates at the figure that fits newer houses.

Why a bigger AC is not better

An oversized unit cools the air before it has run long enough to pull out humidity, so the room feels cold and clammy, and the short on and off cycles waste energy and wear the compressor. ENERGY STAR says an oversized room unit costs more, wastes energy and does not cool better. For central systems, ACCA's Manual S guideline, as summarized by DOE's Building America program, keeps cooling capacity within 15% above the calculated load.

When do you need a Manual J load calculation?

Any time you replace or add a central AC or heat pump. A Manual J calculation, from ACCA (the Air Conditioning Contractors of America), adds up heat gain through each wall, window and ceiling, air leaks, duct losses and the people and appliances inside, using the design temperatures for your town. Ask your contractor for it in writing before you sign, and be wary of a quote that matches your old unit's size without one: many existing systems were sized by a rule of thumb in the first place.

Sources

Room chart, adjustments and oversizing: ENERGY STAR, Room Air Conditioners. Common window unit sizes: ENERGY STAR certified room air conditioners list (608 models, November 2026). Mini split sizes: ENERGY STAR certified air-source heat pumps list. Ton of cooling and the ceiling adjustment: Penn State EGEE 102, 10.7 Air Conditioner Sizing. 20 BTU per sq ft and 1.5 to 5 ton systems: Carrier, What Size Air Conditioner Do I Need? 600 and 1,000 sq ft per ton, and Trane's sizing table: Trane, HVAC Sizing. Manual J loads for code-built houses and Manual S limits: DOE Building America, Strategy Guideline: HVAC Equipment Sizing (Burdick, 2012). Contractor rules of 400 to 600 sq ft per ton against Manual J results: ACCA HVAC Blog, Manual J Load Calculations vs. Rules of Thumb.